All manuals and user guides at all-guides.com
Operation
After completion of these steps, the Busch Transcontrol
operation.
NOTE
The relay is also switched twice if the code was already programmed.
When all 6 Transmitter Modules have been programmed, the reception of a
further code is indicated via the LED; programming is, nevertheless, not effected.
If necessary, cancel the existing programming.
If the Busch Transcontrol
when all 3 send adresses are allocated to a receiver channel, only three further
addresses remain free for this channel.
b. To cancel programming
When the programming is cancelled, all "learned" codes are always cancelled.
To cancel:
• remove the housing if necessary
• select the channel to be cancelled (coding position 1 - 3) and
• hold the programming button (see Fig. 1, Pos. 3) down for approx. 5 secs:
- All programming in respect of the channel selected has been cancelled.
- The LED blinks twice to confirm.
NOTE
To reprogram, proceed as described under a. Provided the programming mode
has not been terminated, several Transmitter Modules or Manual Transmitter
Addresses can be programmed one after the other.
c. Switch Mode (Coding Switch Position 4 to 6)
The Transmitter Module cyclically transmits an ON signal as long as voltage is
connected. HF Receiver 6866 AG switches the corresponding channel or chan-
nels ON.
Should there be a drop in the system voltage, no further orders can be transmit-
ted. After a delay of 15 seconds, HF Receiver 6866 AG switches off.
®
HF Manual Transmitter 6861 is used, please note that,
®
HF System is ready for
GB