Electrical connection
Supply voltage
Output signal
Output current
Electrical connection
Electrical protection
Output
Switching accuracy
Response speed
Linearity, pressure hyster-
esis and reproducibility
Long-term stability
9 ... 36 V DC
10% allowed residual ripple at 50 Hz
1x PNP, 2x PNP
1x NPN, 2x NPN
Max. 500 mA per switch output
M12 plug; German DT04
Cable outlet 1 m; 5 m
Short circuit, signal against GND / 0V
and protection against polarity reversal
≤1.0 % FS (0 – +80 °C / 32 – 176 °F)
≤1.5 % FS (-25 – +100 °C / -13 – 212
°F)
≤2.5 % FS (-40 – +125 °C / -40 – 257
°F)
Typ. 10 ms, max. 20 ms
≤ 0.5% FS
≤ 0.2% FS per year