1.4
High pressure applications
All manuals and user guides at all-guides.com
Selection
When selecting pressure components, ensure that the over-
load pressure will not be exceeded.
It is possible that the pressure cell can be deformed when the
overload pressure is exceeded (depending on the duration, fre-
quency and level of the pressure spike).
The "diesel effect" caused by entrapped air can result in pres-
sure spikes that far exceed the maximum pressure. The nomi-
nal pressure of the pressure component should be higher than
the nominal pressure of the system to be measured.
Installation
ATTENTION
Please follow the instructions and observe the correct tighten-
ing torques for fittings and adapters.
Refer to the high pressure settings specified the catalogues for
the hydraulic fittings and hydraulic hoses.

DANGER