ENGLISH
Line
Mode
AVR
blinks
Mode
blinks
Overload
Battery
blinks
Mode
Troubleshooting
Fault Code
or F03 or F05
F01 / F02
F04 or beeping every 2s
F06
Specifications
Model
Input
Voltage
Voltage Range
Frequency Range
Output
Voltage Regulation
Transfer Time
Waveform
Protection
Humidity
Noise Level
Model
VI 400 SCL
Power
400VA
240W
Capacity
Batteries
4.5Ah x 1
6 hours recover to 90% capacity
Charging
300mm x 101mm x 142mm
Dimension
(DxWxH)
Net weight 3.7kg
All manuals and user guides at all-guides.com
blinks
blinks
blinks
Fault condition
Internal Error
Output short-circuit
/ overload
Weak battery
Over-temperature
VI 600 SCL VI 800 SCL VI 1000 SCL
600VA
800VA
360W
480W
7Ah x 1
9Ah x 1
4.4kg
5.0kg
The screen displays output voltage, input
voltage, load level and battery capacity.
Voltage regulation activated
When overload occurs, alarm will beep
every 0.5s
Output voltage is generated from the
battery. Alarm will beep every 10s.
Solutions
Alarm will continue beeping. Contact technical
support.
Disconnect the loads and restart the UPS.
Please replace the battery.
Turn off the unit, wait until it cools down and
change to a better ventilated environment.
VI SCL Series
230 VAC
162-290 VAC
60/50 Hz (Auto Sensing)
+/-10%
Typical 2-6 ms
Simulated Sine Wave
Overload, discharge, and overcharge protection
0-90 % RH @ 0-40° C (non-condensing)
Less than 40 dB
VI 1500 SCL
1000VA
1500VA
600W
900W
7Ah x 2
9Ah x 2
320mm x 130mm x 182mm
8.2kg
10.4kg
VI 2000 SCL
VI 3000 SCL
2000VA
3000VA
1200W
1800W
9Ah x 2
9Ah x 2
6-8h to 90%
397 x 146 x 205
11.0kg
11.5kg