SECTION 3: INSTALLATION
C: MOUNTING THE FRAME TO THE WALL (continued)
STEP 6:
Attach Bottle Filler assembly to the frame using the four (4) vandal resistant torx screws. Leave the top cap off until after the program is set
for this installation (Figure 15)
STEP 7:
Install the drip tray and anti-splash grate into the al-
cove area and secure with the two (2) stainless steel
Phillips head screws. (Figure 16)
STEP 8:
Connect male tab terminals from bottle filler power
supply to female terminals on power cord. Make sure
male tab is seated inside metal contacts of female
terminal.
STEP 9:
Plug in bottle filler cord. The program should be set
up specific for that installation. See the set up guide
on the next page.
STEP 10:
Turn ON water supply and check for leaks. Place a
bottle in the alcove to release any trapped air from
the system. Plug in the power cord and replace the
front panel. (Figure 17)
STEP 11:
If everything works correctly, place the top cap back
on the bottle filler and use the remaining two (2) torx
screws to fasten it in place. Otherwise, calibrate the
sensor per the instructions on the next page.
10/17 | 036865-047
All manuals and user guides at all-guides.com
Figure 15
Torx screws
Figure 16
Anti-splash
grate screws
(provided)
Anti-splash
grate
Drip tray
Installation completed
Fig
Press
INSTALLATION COMPLETE