7.5 Connecting the hand switch
You can connect the following hand switches to the lifting column:
•
6-key hand switch with display (6-pin hand switch socket) to drive lifting columns, save user-
specific positions and carry out settings
•
8-key hand switch with display and base station (serial connection) to drive lifting columns,
save user-specific positions and carry out settings
If you interconnect a number of lifting columns, the hand switch must be plugged into the cor-
responding socket of the first lifting column (Master lifting column).
7.6 Functional description of the hand switch
7.6.1 6-key or 8-key hand switch
You can drive lifting columns with the hand switch.
You can also store user-specific positions and perform settings with the hand switch.
Use of the hand switch is permitted exclusively in sealed rooms.
Observe the instructions to avoid damage to hand switches.
•
Hand switches may be used only in sealed rooms.
•
Hand switches are to be protected against ingress of liquids.
7. Working life
57