OPERATION
• Open by pressing the control knob.
• Select temperature by turning the control knob.
• Timed automatic shut-off after ~7 seconds for basins and ~30 seconds for showers
(+5/-10 at 3 bar according to the European Norm EN NF 816).
TECHNICAL FEATURES
• Supply with cold water and hot water at 70°C maximum (we recommend 45°C to avoid the risk of scalding).
• The products have been designed to withstand both thermal and chemical shocks in line with current
regulations.
• Recommended pressure 1- 5 bar.
INSTALLATION
• Never remove the non-return valves built into the water inlets (indispensable).
• Fit the connection filters, in the same way as indicated in the instructional images.
Their function is to protect the non-return valves and keep them in place.
THE INSTALLER MUST ENSURE:
THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS STEEL WALL PLATE AND THE WALL,
OR THE WALL PLATE AND THE MIXER AT LEAST ONCE A YEAR, AND MAKE GOOD IF NECESSARY.
If this advice is not followed, water may leak into the wall.
DELABIE cannot be held responsible for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL SUPPORT
UK: 01491 821821. ALL OTHER MARKETS: +33 (0)3 22 60 22 74.
REMEMBER
• Our mixers must be installed by professional installers in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer
(see calculation table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce
the frequency of maintenance (recommended pressure from 1 to 5 bar maximum).
• Install stopcocks close to the mixer to facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should
be checked at least once a year, and more frequently if necessary.
FLOW RATE ADJUSTMENT FIG. 1.I, 2D, 3.G
• The flow rate is pre-set at the factory at 3 lpm at 3 bar for washbasins, it can be adjusted from 1.5 lpm - 6 lpm.
• Shower kits are set at 6 lpm at 3 bar.
• Individual shower mixers are pre-set at 9 lpm at 3 bar and can be adjusted from 6 12 lpm.
EN