Product presentation
Control type
Installation
Electrical connections
Before working on the installation, isolate all
!
electrical supplies.
All electrical wiring must be carried out by a
qualified person.
5 4 3
Coding transmitter with
receiver
!
Important : the transmitter + receiver assembly
is factory coded and is therefore immediately
selection push-
operationnal.
button;
There is no need to recode.
configuration
and forcing
push-button
•
Les instructions ci-dessous sont données à titre
d'information, dans le cas où pour une raison
Output
indication
quelconque vous seriez amené à réaliser un
nouveau codage.
Control type
indication
1.
Set switch 3 at the back
of the transmitter to
CONF position.
The display indicates
CONF.
2.
Press the pushbutton of
the receiver for more
than 3 seconds.
The indicator light
flickers.
3.
Press the Thermoflash transmitter pushbutton
for more than 3 seconds.
4.
The indicator light OK of the receiver stops
flickering, showing that the transmission / reception
link has been established.
5.
Return the switch located at the back of
the Thermoflash transmitter to the
position.
L N
2 1
AUTO
3
CONF
mémo
ok
on/off
OK
AUTO
L
N
L
N
5 4 3
2
1
L
N
L
N
5 4 3
2 1
ON/OFF Priority settings
In the event of problem in your installation, the state
of the output can be priority set to ON or OFF.
Short press (less than 3 seconds) on MEMO key of
receiver.
The contact trips and the LED indicates the change.
- If the output were OFF, it goes ON (the red LED goes
on).
- If the output were ON, it goes OFF (the red LED goes
off).
Important: The RF transmitter has priority over the
above priority settings. This means that any priority
setting will be cancelled as soon the transmitter
transmits a signal.
Total or partial clear
• Total clear
To clear all transmitter/receiver links:
- Press receiver's pushbutton for more than 10 sec.
- The indicator light OK flickers slowly then more
quickly.
+
- Press once again receiver's pushbutton for 3 sec.
- The indicator light OK stops flickering, all codes are
cleared.
The receiver sets back into " AUTO " mode.
•
Partial clear
AUTO
To clear a transmitter/receiver link:
3
- Press receiver's pushbutton for more than 10 sec.
CONF
- The indicator light OK flickers slowly then more
quickly.
- Take the transmitter to be decoded and press for 3
sec the button
+
of the HF thermostat in CONF
mode or on the MEMO button (for other
transmitters)
- The indicator light OK stops flickering, the link
between this transmitter and the receiver is cleared.
The receiver sets back into " AUTO " mode.
Troubleshooting
The heating is not starting.
• The receiver is not fed: (indicator light OK is off).
Check the fuse and the circuit breaker.
• The receiver is out of range of the transmitter.
Move the receiver closer.
•
The receiver does not recognize the code of the
transmitter.
Reconfigure the receiver.
•
Interfering waves disturb the receiver (radio ham, TV
screen, mobile phone relay station...):
Try moving the disturbing waves
sion source.
•
The transmitter is located in a disturbed area:
Move the transmitter out of the area.
If the problem remains, contact your electrician.
transmis-