Mounting
The group controller GC 612-... in
the 6-grid housing is used for the
connection of a group of max. 6 in-
house telephones HTC/HTCV 811-...
In-house telephones connected to
the group controller can be used
buttons 1/6 to call and communicate
with other in-house telephones. The
door station is switched off during
an internal call.
With the GC 612-... it is also
possible to signal a door call to more
than 2 in-house telephones. For this
function HTS/HTSV 811-... units can
also be used.
Several group controllers can be
used in an intercom unit.
In addition, switching and control
functions can be executed from
every connected in-house telephone
HTC/HTCV 811-...
If a door call is made to an in-house
telephone which is currently
conducting a call, this is interrupted
and an engaged signal sounds.
After replacing the receiver the door
call is signalled.
Mounting
1 Mount the Group Controller on
the top-hat rail
2 Surface mounting with accessory
ZN 402-01
Call differentiation
HTC/HTCV 811-...
Main door call: 3-tone chime, storey
door call: 1st and 2nd chime tone
of the three-tone chime, sub-
sequently normal 3-tone chime
Internal call: 3-tone call
Storey call: 2-tone call (ERT button
connected directly at the HTC)
Door parallel call
The door call can be signalled
simultaneously in conventional
systems at up to 2 in-house
telephones. With the GC 612-... it is
possible to signal a door call at up to
6 in-house telephones. This always
actuates two in-house telephones
simultaneously. With more than two
parallel telephones, these are always
called in pairs with a time offset.
4
Speech connection
For each group controller, only one
call can be held. If an internal call
already exists within a group, it is
possible to place an additional call
from the door loudspeaker only to
another in-house telephone which is
not directly connected to the
GC 612-... The group controller acts
in relation to the 1+n side circuit
installation in the same way as an
in-house telephone. Each GC 612-...
requires the NG 602-... for its own
power supply.
Switching and control functions
• Switching and control functions
are possible in conjunction with the
SFC 602-... . A maximum of 6
control functions can be actuated
from each HTC/HTCV 811-... in the
group. Control functions can be
executed at any time with the
receiver down or during an existing
speech connection. Settings at DIL
switch 2 may be necessary in the
in-house telephones HTC/
HTCV 811-...
Operating elements GC 612-...:
• One programming switch in order
to enable the programming mode
• One status LED to display the
programming mode and saving.
• 8 DIL switches to determine the
required functions / for
programming.
• DIL switches 1–6 for assignment of
the door call to the in-house
telephones 1 to 6
• DIL switch 7
ON
= SFC 602-... is connected at
the group controller
OFF
= SFC 602-... is connected at
the door loudspeaker
If DIL switch 7 is set to OFF, DIL
switch 8 is non functional.
• DIL switch 8
ON
= Control functions 5 and 6
act on the SFC 602-...
at the door loudspeaker
OFF
= Control functions 5 and 6
act on the SFC 602-...
at the group controller
Internal call
From each HTC/HTCV 811-... unit in
the group, each other in-house
telephone of the same group can
be called. The following procedure
has to be observed here: Pick up the
receiver and only then actuate the
required call button at the in-house
telephone.
Secondary signal unit
For door call 1 (terminal 7.1) a
potential-free contact S1/S2 is
available at the GC 612-...
(max. 24 V, 2 A).
Installation
The in-house telephones at the
GC 612-... are installed in star
formation.
Maximum conductor lengths
between:
• GC 612-... and telephones
100 m/328 ft.
• GC 612-... and door station
500 m/1640 ft.
Wiring diagram without video
AS-Ta-74/1 on page 36
Wiring diagram with video
AS-TVKa-74-1 on page 56.
As-delivered status of the
GC 612-...
The door call inputs are assigned to
telephones 1:1. Terminal 7.1
(input 1) is assigned to the 1st
telephone, terminal 7.6 (input 6) to
the 6th telephone.