Once calibration has been completed successfully, the information field will display the message "Press
'Analyse'" and the "Analyse" button will become active.
8.1.
Connecting the analyser to the ECS circuit
(1) Connect the end of the test hose to the test connector, pushing the tube until it is fully inserted into
the connector.
(2) Choose the appropriate LP coupler depending on the refrigerant to be analysed (R134a or R1234yf)
and connect the coupler to the ECS circuit. Open the coupler by turning the valve.
(1)
8.2.
Analyse
Once the test hose has been connected correctly, press "Analyse" to start the test procedure. The
information field will then display the message "Analysis in progress" and the progress bar will begin to
move.
The test will take around 2 minutes and 30 seconds.
810G71 - Version V2 – Janvier 2022
(2)
P. 27