NEVER
NEVER LEA
NEVER LEA
SPECIFICATIONS
CAUTION: CSA certified for use with only No. 1-K kerosene fuel.
Factory Tested: Kerosene, Diesel #1 and #2, Fuel Oil #1 and #2, JP8 (Jet A Fuel)
CONSUMPTION RATE
ELECTRICAL DATA
ASSEMBLED DIMENSIONS
APPROXIMATE HEATING AREA
CLEARANCE TO COMBUSTIBLES
OPERATING PRECAUTIONS
Thisisakerosene,direct-fired,radiantheater.It'sintendeduse
isprimarilytemporaryheatingofbuildingsunderconstruction,
alterationorrepair.
Direct-Firedmeansthatallofthecombustionproductsenterthe
heatedspace.Eventhoughthisheateroperatesverycloseto100
percentcombustionefficiency,itstillproducessmallamounts
ofcarbonmonoxide.Carbonmonoxide(calledCO)istoxic.CO
canbuildupinaheatedspaceandfailuretoprovideadequate
ventilationcouldresultindeath.Thesymptomsofinadequate
ventilationare:
•
Headache
•
Dizziness
•
Burningeyesandnose
•
Nausea
•
Drymouthorsorethroat
BesuretofollowadviceaboutventilationintheSafetyPrecautions
section.
ForcedAirmeansthatablowerorfanpushestheairthroughthe
heater.Propercombustiondependsuponthisairflow;therefore,
theheatermustnotberevised,modifiedoroperatedwith
partsremovedormissing.Likewise,safetysystemsmustnotbe
circumventedormodifiedinordertooperatetheheater.
Whentheheateristobeoperatedinthepresenceofotherpeople
theuserisresponsibleforproperlyacquaintingthosepresentwith
thesafetyprecautionsandinstructions,andofthehazardsinvolved.
SAFETY PRECAUTIONS
1.
RecommendedforusewithNo.1-Kkerosenefuel.Factorytested
forusewithNo.2-Kkerosene,No.1orNo.2Diesel,No.1orNo.2
fueloilorJP8JetAfuelandthesefuelsmaybeusedaswell.Never
usegasoline,biodiesel,oildrainedfromcrankcases,naphtha,paint
thinners,alcoholoranyotherhighlyflammablefuels.
2. Checktheheaterthoroughlyfordamage.DONOToperatea
damagedheater.
3. DONOTmodifytheheateroroperateaheaterwhichhasbeen
modifiedfromitsoriginalcondition.
4. Suitableforoutdooruse.Foreitheroutdoororindooruse
whereadequateventilationisprovided.Neveruseinareas
normallyforhabitation.Notforusewhereexposedtoweather.
5. Useinwellventilatedareas,provideatleast2sq.ft.(0.19sq.
m.)ofopeningnearthefloorand2sq.ft.(0.19sq.m.)near
theceilingdirectlytooutdoors.Increaseairopeningsasmarked
foreachadditionalheater.
6. Alwayskeepcombustibles,likepaperandwoodatleast8ft.
fromtheheateroutletand3'fromthetop,sidesandinlet.
Mr. Heater, Inc. | Kerosene Fired Radiant Heater
LEAVE THE HEA
VE THE
VE THE HEA
HEATER UNA
TER
TER UNA
Model
BTU
TANK CAPACITY
RUN TIME
DRY WEIGHT
FULL WEIGHT
UNATTENDED WHILE BURNING!
TTENDED WHILE BURNING!
TTENDED WHILE BURNING!
MH125KTFR
125,000BTU/HR.
.96GAL/HR.
9.25GALLONS
10HRS.
120v60Hz
22.5"X34.5"X38"
66LBS.
129LBS.
3125SQ.FT.
OUTLET8'SIDES3'
Locate8ft.fromcanvasorplasticcoveringsandsecurethem
topreventflappingmovement.
7.
Caution:Duetothehighsurfaceandexhausttemperatures,
adultsandchildrenmustobserveclearancestoavoidburnsor
clothingignition.DoNotTouch.Keepchildren,clothing,and
combustibleaway.
8. Installtheheatersuchthatitisnotdirectlyexposedtowater
spray,rainand/orwater.
9. Neveruseinareasnormallyforhabitationand/orwhere
childrenmaybepresent.
10. Alwaysoperateonlyonastable,levelsurface.
11. Donotusewithductwork.Donotrestrictinletorexit.
12. Useonlywithelectricalpowerspecified.Theelectrical
connectionandgroundingmustcomplywithNational
ElectricalCode–ANSI/NFPA70(USA)andCSAC22.1
CanadianElectricalCode,Part1(Canada).
13. Useonlyaproperlygrounded3prongedreceptacleor
extensioncord.
14. Donotmove,handle,orservicewhilehotorinoperation.
15. Useonlyinaccordancewithlocal,state(provincial)or
nationalrequirements,ordinancesandcodes.
OPERATING INSTRUCTIONS
UNPACKING
1. Removeheaterfromcarton.
2. Removeallprotectivematerialwhichmayhavebeenapplied
totheheaterforshipment.
3. Checktheheaterforpossibleshippingdamage.Ifany
damageisfoundimmediatelycontactthemanufacturerat
800-251-0001.
ASSEMBLY
Handlesandsafetyguardsarefoundintheshippingcartonalong
withmountinghardware.
MH125KTFR
1. Locatethetransporthandleshippedwithyourunit.Along
withthefourPhillipsheadedscrews,nuts,andwashers.and
installthemtwosetsperside.
2. Locatetheradiantsurfaceguardshippedwithyourunit.
NextlocatethefourPhillipsheadedscrewsincludedwiththe
hardwarepackageandattachtheguardtothefourguard
connectionpointslocatedatapproximatelythe2o'clock,
4o'clock,10o'clock,and8o'clock positionswhenlooking
atthefrontofyourheater.IflocatedinCanadayouhave
anadditionalDrapeguardtoinstallabovethefrontradiant
surfaceguard.Theguardandfastenersareprovided.
3
Operating Instructions and Owner's Manual
MH70KTFR
70,000BTU/HR.
.52GAL/HR.
2.77GALLONS
5.34HRS.
120v60Hz
13.25"X25"X22.25"
40LBS.
58.89LBS.
1750SQ.FT.
OUTLET8'SIDES3'