Troubleshooting
Problem
Possible cause
Cables or connectors defective.
If cables and connectors have
Height adjustment
been checked a possible cause
does not work
could be a defective UP and DOWN
switch.
Error in the control unit.
If your problem couldn´t be solved or is not listed here, please contact your customer
service for further advise.

Connecting the electrical components

Before putting the table into operation:
screw all components tightly together!!
under the desk.
Keep in mind that the desk which you are assembling is height adjustable. The cables of the
electrical components must be able to freely follow the movement of the desk
8
The control unit
with the "Gyrosensor" must be in a horizontal position and screwed tight!
Please carry out "Reset" now
Reset
Carry out a "Reset" at regular intervals - at least 1 x per month.
16
VXMKA
English
Solution
Check cables for damages and if
necessary replace them. Power in order?
Replace UP and DOWN switch.
Initialize restart.
RESET -
obligations prior to initial operation
Before initial operation the table
must be in the correct position,
the control unit with the "Gyrosensor" must be in a horizontal position and screwed tight according to
the assembly instructions,
the power must be connected,
a reference drive "RESET" must be carried out on the table.
Before each use, make sure that neither objects, persons nor animals are in the way of the height
adjustment.
If it is necessary to disconnect the cables from the motor or the control unit, always disconnect the power
supply unit from the electricity supply beforehand.
• If at any time the rack should no longer function properly, always carry out
• Please repeat the reset at regular intervals, e.g. 1x per month!
resolved by carrying out a RESET drive.
replacement of parts
RESET-MODE
operated in the reset-mode.
As long as the reset-mode is enabled, the system can only move downward. To end the reset-mode and
use the system normally, please follow the next steps:
Press and hold "UP" and "DOWN"
simultaneously more than 3 seconds.
RESET
Keep pressing "UP" and "DOWN".
Release "UP" and "DOWN" together.
The system can be operated normally now. Press and hold the "UP" or "DOWN" button to move the system
to the desired height.The system stops when you release the buttons.
The initialization procedure must be completed.
UP
Down
English
VXMKA
02/2021
Legs begin to move down at a half speed of
normal operation.
Legs move down to the lowest position and
rebound 2-5 mm,
then stop.
Initialization is completed.
114415 MNMONT_XMKA -RESET