PEDESTAL FIXING Fig.1
The filter pump must be vertically fixed on ground or a certain
pedestal made of wood or concrete before use. There should
be two holes 7mm in diameter on the pedestal, the space
between which should be 256mm. Put filter pump on the
pedestal and fix them together by fasten the bolts and nuts. All
the pedestal parts should weigh over 18kgs at least to prevent
the pump from accidental falling.
OPERATION
1) Open/unscrew the Air Purge Valves on the Filter Pump; air is released as water fills the Filter Pump.
2) When water comes out of the Air Purge Valves, close both the Air Purge Valves and wipe away any water.
3) To start the Filter Pump, insert the plug.
4) Turn on the switch to the " I " position.