Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Water Leakage Test

The final test after loading the camera is explained below. Always perform this test. It can be performed
easily in a water tank or a bathtub. Confirm the operation of the different buttons. The required time is
about 5 minutes.
• At first, immerse the Case for only 3 seconds and check that no water enters the Case.
• Next, immerse the Case for 30 seconds and check that no water enters the Case.
• Then, immerse the Case for 3 minutes, operate all buttons and levers, and check the following:
- check that no water drops have the entered the Case.
- check that the Case is not fogged internally.
- check that no water has entered the Case.
• If the inside of the Case becomes fogged or there are water drops in the Case, repeat the maintenance
of the O-ring (P.11) and perform the water leakage test again.
EN
EN 15

Publicité

Table des Matières
loading

Table des Matières