INSTALLATION, OPERATING INSTRUCTIONS AND OWNER'S MANUAL
READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION OF YOUR
PLEASE RECORD THE SERIAL NUMBER ______ OF YOUR WHIRLPOOL AND SAVE THIS MANUAL
NOTE: These instructions are to be used along with the installation instructions for
WARNING - When using electrical products, basic
precautions should always be followed, including the
following:
DANGER:
Risk of electrical shock. Connect only to a
circuit protected by a ground fault circuit interrupter, (GFCI).
Grounding is required. An equipment grounding terminal is
provided in the field wiring compartment. To reduce the risk of
electric shock, this terminal must be connected to the
grounding means provided in the electric supply panel with a
conductor equivalent in size to the circuit conductors
supplying the equipment.
Install this unit in accordance with the Canadian electrical
code, part 1 or the appropriate code in other countries.
Install to permit access for servicing.
Provide adequate ventilation for the motor to prevent
nuisance trips of the thermal overload protection.
Caution: Do not lift a whirlpool bath by its plumbing.
Handle it by the bath shell only.
DRAIN & OVERFLOW LEAK TEST
Test the installation after completing the plumbing, but before
enclosing the bath and finishing the surroundings. Fill the bath
with water and leave it for one hour to ensure that the
adjustment of the drain-overflow assembly is correct, and that
there are no leaks.
WHIRLPOOL FITTINGS LEAK TEST
Do not run the whirlpool pump unless the bath is filled with
water to a level at least 2" (50 mm) above the whirlpool fittings.
Press the tub-mounted air switch control (A/S) to start the
pump. Run the pump and jets for 10 minutes to ensure there
are no leaks around the whirlpool fittings. Press the air switch
control (A/S) again to stop.
INSTALLATION NOTES
Important: All Mirolin acrylic whirlpools receive a thorough
water test and are carefully inspected and packed for
shipment. You should check your unit for any problems. For all
installation and product related inquiries contact Mirolin
customer care at 800.MIROLIN before installation. Do not
contact retailer.
Protect the bathtub and fittings from dirt and damage by
leaving the polyethylene protective film in place until
installation and other related construction is complete. Access
ACRYLIC WHIRLPOOLS
WHIRLPOOL HYDROMASSAGE BATHTUB
FOR FUTURE REFERENCE.
ACRYLIC BATHTUBS
for servicing the pump and controls of the whirlpool bath
must be provided (Refer to specification drawings for
location). DO NOT remove or relocate the pump from its
factory-installed position. This position ensures proper
priming, drainage, and performance of the whirlpool
system.
Relocating the pump will void the warranty.
NOTE: The unions for the piping at the pump are only to
be hand tightened. Check by hand that they have not
loosened during shipping.
MODELS WITH INTEGRAL APRON
Whirlpools with an integral apron have a removable
panel in the apron for access to the pump and motor. The
panel is fastened to the apron by strips of interlocking
fabric along the top plus screws.
To remove panel follow instructions below:
Figure 1 - Integral apron with removable panel.
To remove the panel, first expose the screws by
removing all 5 plastic caps. Use a flat screwdriver gently
to avoid scratching the acrylic bathtub, Figure 2.
1
mirolin.com
Plastic cap
R0084092, Rev. B

Publicité

Table des Matières
loading

Sommaire des Matières pour Mirolin Phoenix PA6030L

  • Page 1 Press the air switch control (A/S) again to stop. INSTALLATION NOTES Important: All Mirolin acrylic whirlpools receive a thorough water test and are carefully inspected and packed for shipment. You should check your unit for any problems. For all installation and product related inquiries contact Mirolin customer care at 800.MIROLIN before installation.
  • Page 2: Electrical Connections

    Minimum height for NEMA plug as per the standard is  INSTALLATION CLEAN-UP 38 mm, but Mirolin Industries’ recommended safe zone height is 305 mm (12”). Figure 7. Refer to the Installation Instructions and Owner’s Manual for Receptacle shall be installed outside the exclusion the Acrylic Bathtubs for information on cleaning and ...
  • Page 3  Warning: risk of accidental injury or drowning: do not is running. use whirlpool bathtub unless all suction guards are installed to The flow of water can also be increased by turning the jet face plate clockwise and decreased by turning prevent body and hair entrapment;...
  • Page 4: Electrical Connection

    then remove power from the heater by resetting the circuit Fainting  breaker at the main electrical panel. If the High-Limit trips The effects of hyperthermia include: frequently, contact a qualified service technician. Failure to perceive heat  Vacuum Switch: In the event the pump is not running or if Failure to recognize the need to exit the bath ...
  • Page 5 Figure 9 - Suction Return Fitting We want you to be completely satisfied with our products and service. If you have any comments or suggestions, please call 800.MIROLIN(647-6546) toll free. The company reserves the right to change models and specifications without notice.
  • Page 6 PART IDENTIFICATION REFERENCE WHIRLPOOL SYSTEM DRAWING DESCRIPTION KEY DESCRIPTION 1-1/2” (38mm) Breaking Union Electrical motor & pump Air switch on/off for pump Pump union Air switch gasket 1-1/2” (38 mm) Suction pipe Air switch PVC nut 1-1/2” (38 mm) Pressure union 10.0 Air check valve Suction elbow 90 deg.
  • Page 7 à moins qu'il ne soit arrêté plus bientôt en appuyant sur le baignoire en acrylique, Figure 2. bouton une deuxième fois. Mirolin Industries Corp. décline toute responsabilité en cas de dommages résultant du défaut d'effectuer ce test de fuite avant utilisation par le client.
  • Page 8: Nettoyage De L'installation

     CONNEXIONS ÉLECTRIQUES. NEMA comme montré dans la figue 3 est 38 millimètres dans la norme, mais les Industries Mirolin’ Obtenez les services d'un électricien qualifié pour faire ont recommandé que la hauteur zonale sûre est 305 l'installation électrique et vous assurer que toutes les exigences millimètres (12 po).
  • Page 9 En aucun cas, la règle est de ne jamais utiliser la pompe sans IMPORTANTES DIRECTIVES DE SÉCURITÉ l'écran sur le retour d'aspiration LISEZ, SUIVEZ ET CONSERVEZ CES DIRECTIVES INSTRUCTIONS D'UTILISATION Avertissement : risque de blessure ou de noyade: les  enfants ne doivent jamais utiliser une baignoire à...
  • Page 10: Instructions D'entretien

    Le «GFCI» devrait être fourni par l'installateur et devrait être vérifié sur une base routinière. Pour vérifier le «GFCI», appuyez sur le bouton «TEST», la chauffe-bain ne devraient pas fonctionner. Appuyez sur le bouton «RESET» et la chauffe-bain devraient fonctionner de nouveau. Si le «GFCI»...
  • Page 11 Figure 9 - APPAREILLAGE DE RETOUR DE SUCCION otre entière satisfaction nous importe. En cas de commentaires ou de suggestions, composez le numéro sans frais le 800.MIROLIN(647-6546). La société se réserve le droit de changer les modèles et les spécifications sans préavis.
  • Page 12 IDENTIFICATION DES PIÈCES RÉFÉRENCE DU DESSIN DU SYSTÈME DE BAIN TOURBILLON DESCRIPTION DESCRIPTION Moteur électrique et pompe Raccord-union de rupture 1-1/2 po, 38mm Raccord de pompe L'air allume / de la pompe Tuyau d'aspiration 1-1/2 po, 38mm Joint de changement aérien Raccord de pression 1-1/2 po, 38mm Changement aérien noix de PVC Coude d'aspiration de 90º...
  • Page 13 If repair or replacement is DAMAGES not practical, Mirolin Industries Corp. may elect to refund the purchase price (the return of the product may be required at Mirolin Industrie Corp. option). Mirolin Industries Corp.
  • Page 14: Garantie Limitée

    Ceci est la garantie écrite exclusive de Mirolin Industries Corp. et la garantie n’est pas défaut de suivre les instructions de soins et de nettoyage applicables. Mirolin Industries transférable.

Ce manuel est également adapté pour:

Phoenix pa6030rTucson ta6032lTucson ta6032r

Table des Matières