1) Diagnosis
Check the battery's initial condition, including voltage, state-
of-charge and health, to determine if the battery is stable
before charging.
2) Desulphation
Use voltage or high-frequency pulses to break down the
sulfates that have built up over time in the aging battery, to
extend battery life and optimize battery performance."
3) Pre-Charge
Start the charging process with a gentle stable current until
the battery capacity returns 25%. This reduces the stress put
on batteries by sudden surges."
4) Soft Start
Provide a medium stable current until the battery capacity
returns 50%.
5) Bulk Charge
Begin the Bulk charging process based on the condition of
the battery until the battery capacity returns 80%."
6) Absorption
Bring the charge level to 100% by delivering small amounts of
current to provide a safe, efficient charge. This limits battery
gas emission and prolongs battery life.
7) Analysis
Monitor whether the battery voltage falls below its target
threshold, if yes, the charger will enter the Recondition mode.
8) Recondition
Check the battery status, and then recover the small current
to improve the battery capacity."
9) Maintenance
Check the battery status and bring the charge level back to
100%. Then the Analysis, Recondition and Maintenance will
form into a charge cycle to keep the battery at full charge.
The battery charger can be safely left connected indefinitely
without the risk of overcharging.