DARDO 430
DARDO 430
FITTING THE POWER SUPPLY CABLE
GATE OPENING INWARDS
IMPORTANT: the terminals of M1 (A1, B1, C1 and D1, E1, F1) and M2 (A2, B2, C2 and D2, E2, F2) motors in
!
the controller correspond to:
- M1 = Dardo on 1st gate leaf to open and in pedestrian mode if selected.
- M2 = Dardo on the gate leaf delayed in opening.
IMPORTANT: on single gate installations where only one operator is mounted, it is sufficient to connect the
!
motor to M1 and bridge E1 with E2, while A2, C2, B2, D2 and F2 terminals are not connected.
Dardo terminals
230 V
encoder
D-
E
F+
A
common
A
C
A2
C2
Attention:
!
230 V power supply output
D2 E2 F2
electromechanical operator for swinging gates
Once the electrical
connections are finished,
tighten the gland locknut
Let the cable dangle free
avoiding sharp bending
Dardo M2
B
B
B
B2
Dardo M1
Dardo terminals
encoder
D-
E
F+
3 x 0,5 mm²
ELPRO 43
D1
E1
F1
Pic. 15
23
Terminal block for
electrical connections
230 V
encoder
D-
E
F+
A
common
230 V
A
B
B
common
C
A
B
4G x 1,5 mm²
A1
C1
B1
Attention:
!
230 V power supply output
B
B
Pic. 14