21. Do not place any objects on the device.
22. The device can be used only with properly working ventilation.
23. To provide additional protection, it is advisable to install a residual current device (RCD)
in the electric circuit with a rated residual current not exceeding 30mA. Ask an
electrician for this.
Before first use
1. It should be remembered that a high level of humidity may favor the development of biological organisms in the environment.
2. Do not get wet the device or wet the area around the device. If moisture appears, reduce the efficiency of the humidifying function.
3. Do not allow absorbent materials such as carpets, curtains, tablecloths to get wet.
4. Never leave water in the tank when the device is not in use.
5. During filling and cleaning, disconnect the device from the mains.
6. Clean the device and water tank before using it again.
• WARNING: When the water is not replaced and the tank is not properly cleaned every 3 days, microorganisms that may be present in
the water or in the environment where the device is used or stored may develop in the water tank and be blown out to the
surroundings. This can cause a very serious health risk.
• WARNING: Every three days, empty the water tank and top up with clean water. Before refilling, clean the tank with fresh tap water or
using detergents. Remove any scale, deposits or film that has formed on the sides of the tank and on the interior surfaces. After
washing, wipe all surfaces dry.
DESCALING
1.Perform the descaling procedure in accordance with the instructions of the descaling agent specified by the manufacturer.
2.Use descaling agents intended for this purpose.
3. Carry out the descaling procedure at least every 3 months.
4. Descaling only the water tank with the device turned off.
PRODUCT DESCRIPTION – TOWER AIR COOLER AD7859 – picture A
1. Handle
3. Air outlet
5. Filter
7. Cover with net
9. Power cord
11. Pump
13. Water tank lock
15. Brackets
Remote control & Control panel – picture B
A – power button
B – speed button
C – oscillation button
D – mode button
E – timer button
F - wet cooling button
USING THE DEVICE
A noticeable reduction in the temperature of the outlet air occurs after putting into the water tank (8) the plastic containers (12) attached
to the product. The plastic containers should be previously frozen in the freezer for few hours. It is recommended to fill the plastic
container (12) with cold tap water and do not exceed MAX level marked on the plastic container. The content of plastic container is
prohibited to edible. Keep away from children.
1. Place the unit on a dry, flat surface.
2. Rotate to flat position the water tank lock (13) and pull out a little the water tank (8) from the back of the device. Use the jug to pour
clear, cold water, be careful not to exceed the maximum level. You can pour water w/o pulling out the water tank completely. To
remove water tank completely, look at picture E. First remove the pump (11) by releasing the two black brackets (15) and pull out the
water tank (8). After water pouring, turn the water tank lock (13) to horizontal position. Do not tilt the device after pouring the water to
water tank. Do not remove water tank while the device is plug in power supply.
3. Connect the plug to power supply, the device is in standby mode. The LCD display showing ambient room temperature is illuminated.
Now can be used control panel (2) or remote control (14) to operate the device (figure B).
Turn on the device using the power button (A). The device starts working in middle speed. Press the button (A) again to switch it back to
standby mode.
4. The button (B) allows you to change the speed of the fan. The following speeds can be selected: fast, medium and slow. The
corresponding icons on the panel will light up.
5. The wet cooling button (F) lowers the temperature of the air by running the water pump. Press the button (F) only when water level
exceed MIN in the water tank. Additionally, a set of two plastic containers (12) is attached. Plastic containers (12) should be filled by
cold, tap water and do not exceed maximum level. Next, put them on several hours inside the freezer. Then put one or both of
containers into water tank (8). To blow the wet cool air, the device must be filled with water. When the device is operating,
2. Control panel
4. Base
6. Screw
8. Water tank
10. Water level indicator
12. Plastic containers
14. Remote control
5