Gas Connections
Never connect a gas line directly to the grill. A pressure regulator must be installed on all gas
equipment. All local codes require a pressure regulator and NewAge supplies the correct regulator
with your grill. Removing or failing to install the pressure regulator can result in fire, and serious
personal injury and will void the warranty. This grill is designed for non-combustible enclosures
only, and must be installed and serviced by a licensed gas fitter to local codes.
As indicated on the rating plate, this gas grill is designed to operate with gas supply pressures
of 7" WC for Natural Gas. For installations where the gas supply pressure exceeds these
requirements, a regulator must be installed upstream of the grill's components. If the gas supply
pressure is lower than these requirements, the unit will be under-fired and will not reach the
maximum temperatures. Ensure that the supply line size complies with local and/or national
installation codes.
The grill is factory set to use natural gas (NG). It is critical that the gas you use matches that which
the grill was set up for.You can verify that by checking the rating plate.
CLASS NO / CATÉGORIE #: 2711 04/84
WARNING:
TURN OFF GAS SUPPLY AT MAIN VALVE WHEN NOT IN
NEWAGE PERFORMANCE 40" GRILL
USE. IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE CAUSING
DEATH OR SERIOUS INJURY MAY OCCUR.
NATURAL GAS
OUTDOOR COOKING APPLIANCE- FOR OUTDOOR USE ONLY. DO NOT USE THIS
1 3/4"/32 MM
APPLIANCE UNDER OVERHEAD COMBUSTABLE SURFACES. ONLY FOR
ATTENTION:
COUPER L'ALIMENTATION EN GAZ DE LA VANNE
INSTALLATION IN A BUILT-IN ENCLOSURE CONSTRUCTED OF NON-COMBUSTION-
PRINCIPALE LORSQU'ELLE N'EST PAS UTILISÉE. SI CES INSTRUCTIONS NE SONT
ABLE MATERIALS. / APPAREIL DE CUISINE DE PLEIN AIR- POUR UTILISATION À
PAS SUIVIES EXACTEMENT, UN INCENDIE CAUSE LA MORT OU DES BLESSURES
L'EXTÉRIEUR SEULEMENT. NE PAS UTILISER CET APPAREIL SOUS UNE SURFACE
GRAVES PEUVENT SURVENIR.
COMBUSTIBLE. CONVIENTUNIQUEMENT POUR INSTALLATION DANS UNE
ENCEINTE ENCASTRÉE FAITE DE MATÉRIAUX INCOMBUSTIBLES.
Rating Plate - Lists model numbers and gas type
Water Column Requirements
Fuel
WC Min Under
Full Load
NATURAL GAS
7 in wc (NG)
The rating plate is located in one or more of the following places:
On the back of Grill
Ensure that the gas supplied meets with the minimum pressure requirements. Do not operate the
grill on any gas other than that for which the grill has been set.
Both the regulator and the manifold orifices have been tuned for the type of gas specified on the
rating plate.
All installation and all installation parts must conform to local codes with the National Electrical
Code, ANSI Z223.1/ NFPA 70 latest edition and the National Fuel Gas Code, ANS Z223.1/NFPA 54
in the U.S. and CGA-B149.1/.2 in Canada. Canadian installations must conform to CGA-B149.1/.2
natural gas/propane installation code. (Canada)
WARNING
CAUTION:
MODEL/ MODÈLE
THIS APPLIANCE IS ADJUSTED AND SHIPPED FOR USE WITH NATURAL GAS. THIS
GAS GRILL IS DESIGNED TO OPERATE WITH GAS SUPPLY PRESSURE OF 7" WC FOR NATURAL GAS. IF THE
PERFORMANCE 40" GRILL-
GAS SUPPLY PRESSURE IS LOWER THAN THESE REQUIREMENTS, THE UNIT WILL BE UNDER-FIRED AND
WILL NOT REACH THE MAXIMUM TEMPERATURES. ENSURE THAT THE SUPPLY LINE SIZE COMPLIES WITH
NG
LOCAL AND/OR NATIONAL INSTALLATION CODES.
PERFORMANCE 40"GRILL -
AVERTISSEMENT:
NG WITH 40" GRILL CART
CET APPAREIL EST RÉGLÉ ET EXPÉDIÉ POUR UTILISATION AVEC DU GAZ
NATUREL. CE GRIL À GAZ EST CONÇU POUR FONCTIONNER AU GAZ PRESSION D'ALIMENTATION DE 7 "WC
EQUIPPED FOR USE WITH
POUR GAZ NATUREL. SI L'ALIMENTATION DE GAZ LA PRESSION EST INFÉRIEURE À CES EXIGENCES, L'UNITÉ
SERA SOUS-CUIT ET N'ATTAQUE PAS LES TEMPÉRATURES MAXIMALES. ASSUREZ-VOUS QUE LA TAILLE DE LA
NATURAL GAS / GAZ NATUREL
LIGNE D'ALIMENTATION EST CONFORME AUX CODES D'INSTALLATION NATIONAUX.
MINIMUM CLEARENCE FROM SIDES AND BACK OF UNIT TO COMBUSTIBLE
3 X 12,000 BTU/ MAIN TUBE BURNERS / BRÛLEURS À
CONSTRUCTION, 14 INCHES FROM SIDES, AND 18 INCHES FROM BACK.
TUBES PRINCIPAUX
ONLY FOR INSTALLATION IN A BUILT-IN ENCLOSURE CONSTRUCTED OF
66982
X
1 X 12,000 BTU/ IR SEAR BURNER/BRÛLEUR SAISIR
NON-COMBUSTIONABLE MATERIALS OR NEWAGE GRILL CABINETS. SEE
INFRAROUGE À HAUTE TEMPÉRATURE
MODELS.
DÉGAGEMENT MINIMAL ENTRE LES PAROIS LATÉRALES ET L'ARRIÈRE
66281
NATURAL GAS/ GAZ
ORIFICE SIZES/ GRANDEUR DES ORIFICS
NATUREL
DE L'APPAREIL ET LA CONSTRUCTION COMBUSTIBLE, 14 POUCES À
PARTIR DES PAROIS LATÉRALES ET 18 POUCES À PARTIR DE
MAIN BURNERS/ BRÛLEUR PRINCIPAL
1.39MM
L'ARRIÈRE. UNIQUEMENT POUR L'INSTALLATION DANS UN BOÎTIER
SEAR STATION BURNER/BRÛLEUR
1.39MM
INTÉGRÉ CONSTRUIT DE MATÉRIAUX NON COMBUSTIBLES OU POUR
INFRAROUGE
APPAREIL DE GRILLE ET D'ARMOIRES NEWAGE.
23 "/ 584.2 MM
GRILL PULSE IGNITOR REQUIREMENTS:
INPUT- AA BATTERY
111 CREDITVIEW ROAD, 2nd FLOOR
(Rechargeable and Non-Rechargeable)
L4L-9T1
MFG DATE DE FABRICATION :
Class IIIA-2
Supplier to APPLY
PRODUCTION CODE STICKER
C
US
ANS Z21.58-2018•CSA 1.6-2018
Outdoor Cooking Gas Appliances
25