Do not use an adjustable pressure reducing valve.
Gas supply hose should not pass through the hot section behind the oven.
Temperature of the gas hose should not exceed 90°C (degrees).
Prior to use, make sure the system is gastight.
(Figure 4)
NG (natural gas) connection
If your equipment is set for natural gas, you should have it connected by an installer
registered with the natural gas distribution company. Natural gas connection of your
equipment is 1/2".
If you desire to convert your equipment from LPG to natural gas or from natural gas to
LPG, please call the nearest service center for gas conversion settings.
LPG - NG, NG – LPG conversions;
Figure 6
Figura 6.4
1-
G1/2 nipple (union)
2-
Silicone gasket
3-
G1/2 Hose inlet (gas inlet)
4-
Metal clamp
5-
Gas hose (inner diameter 8mm)
1-
G1/2 nipple (union)
2-
Silicone gasket
3-
G1/2 NG hose ( natural gas hose as per EN
14800
Figure 6.1
Figure 6.2
Remove the burner cover and burner as shown in the Figure 6. Remove
the injector by help of 7's socket screw driver as shown in the Figure 6.1.
Fix the injector (D) you want to convert as shown in the Figure 6.2. (see
Table 1)
Put the burner in place again as shown in the Figure 6.3. Upon completion
of the conversion, then burn the burners in order and remove the switch
on the control panel and adjust the low flame length by tightening or
untightening the screw on the gas valve (Figure 6.4 cock) or inside the
valve shaft.
)