noken SMART PLUS PROGRAM Mode D'emploi page 18

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
ENG
Connection to Fil-Pilote system
(To be used by installer only)
1) Smart Plus Program with "Fil-Pilote" function (Class II) can be remotely
controlled by a remote control unit supporting the "Fil-Pilote" standard. The
brown wire is the Live wire (L), the grey wire is the Neutral wire (N) and the black
wire is used for receiving the Fil-Pilote signal.
Do not connect the black wire to the ground
2) Smart Plus Program without "Fil-Pilote" functionality (Class I) cannot be
remotely controlled. The brown wire is the Live wire (L), the blue wire is the
Neutral wire (N) and the yellow/green wire has to be connected to Earth.
18

Publicité

Table des Matières
loading

Table des Matières