Following thermostats are approved to be used:
T2FloorTemp and TA thermostat with floor sensor limited to 30°C
T2DigiTemp, TC, NRG-Temp, NRG-DM, Green Leaf, SENZ and SENZ
WIFI thermostat with floor sensor limited to 35°C. It is recommended
to install the sensor cable in a conduit (included), so that it is
possible to replace a defective sensor easily. The conduit must be
sealed properly by means of the cap (included). The sensor itself
should be located close to the surface immediately under floor tiles
or other floor covering and should be positioned centrally between
two heating cables. Avoid mechanical damage to the heating cable !
Strive for a positioning of the floor sensor as close as possible to the
top floor surface for best temperature control. When installing two
heating mats, the sensor should be positioned between these two
mats. In case of damage a splice kit can be used. Please observe all
applicable regulations concerning installation.
Attention:
This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in
a safe way and understand the hazards involved. Children shall not
play with the appliance. Cleaning and user maintenance shall not
be made by children without supervision.
Technical data
Nominal voltage
Power output
Circuit breaker
Min. bending radius
Min. cable spacing
Max. exposure temp.
Min. installation temp.
Conductor cross-section
of cold lead cable
Length of cold lead cable 2,5 m
Approvals
QuickNet-N
AC 230 V
up to 90 W/m²
See Fig. C and D
30 mm
90 mm
+90°C
+5°C
3 x 1,0 mm²
VDE
SEMKO
QuickNet-P
AC 230 V
up to 160 W/m²
30 mm
70 mm
+90°C
+5°C
3 x 1,0 mm²
5,0 m
VDE
SEMKO