oneConcept MCH-1 V2 Manuel D'utilisation page 21

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Cooling function
Note: The cooling function can only be switched on when the fan is in operation.
Before operating the unit in cooling mode, check the proper position
of the water tank. Then, fill with clean, cold water. Observe the water
level indicator to avoid overfilling. Press the Cool button after filling the
water, and the appliance will start blowing cooler air. To increase the
cooling effect, you can additionally place the cold pack in the water tank.
Notes: Before using the cold pack, you must remove the lid and pour in clean,
cold water until the maximum water level is reached. Overfilling can cause
the pack to burst. Put the lid back on and place the cold pack in the freezer
compartment of your refrigerator or in a freezer for 1 to 2 hours until the water
is completely frozen.
Always pull out the water tank for cleaning. Be careful not to break off
the intake manifold.
Removing the honeycomb evaporator for cleaning purposes
1
Pull out the air filter upwards.
2
Turn the small lever upwards.
3
Remove the honeycomb
evaporator.
4
Clean the air filter and
honeycomb evaporator with
warm tap water. Also remember
to clean the filter with a mild
soap solution and only replace it
when it is dry.
EN
21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

10029739

Table des Matières