Cleaning the filter and the aerator
If the water flow has decreased, this may be because the filter is clogged. Clean the filter as follows:
Cleaning the filter
6110 (see Figures 1 and 3)
– Shut off the water supply to the faucet.
– Remove the connecting hose (7) from the control box.
– Unscrew the connecting nipple (8) and remove the strainer from the nipple.
– Clean the strainer under running water.
– Reassemble the parts.
6114 (see Figure 5)
– Shut off the water supply to the faucet.
– Unscrew the nipples (8) from the valve housing and clean or change the strainer (18)
– Reassemble the parts.
Cleaning the aerator (see Figure 6)
– Unscrew the aerator (30) with a special key (31).
– Clean the strainer under running water and replace if necessary.
Changing the temperature regulator (see Figure 7)
Troubleshooting
Symptom
Water flow from the outlet
does not stop, or stops
after 2 minutes
Water flow is low and weak
No water comes out of the faucet
14 (52)
Cause / Solution
– The sensing range is too low
– Check that the photocell is clean
– The solenoid valve is damaged
– The filter or aerator is clogged
– Check the water supply to the control box
– The solenoid valve is damaged
– Power failure
– The sensor is covered or damaged
– Check the fuse (17) inside the control box: 0.1 A