Instruction manual
6
Technical specifications
For reference, please see the Planning Fundamentals which are available for download at
http://www.gfps.com
>> Support and Services >> Planning Assistance >> Planning Fundamentals >> Planning
Fundamentals Industry
Data
Control medium
Compressed air class as defined in
ISO8573-1
Max. permitted control pressure
Max. permitted control pressure
for FC/FO
Actuator connection
Control time
Actuating angle
Effect
Position indicator
Housing material
Ambient conditions
Permitted ambient temperature
Permitted air humidity
Control volume
PA11
PA21
36
Kv value
Compressed air
2 or 3 at -10 °C,
3 or 4 at T > 0 °C
7 bar
4.5 bar
Rp1/8''
1 – 2 s, with throttle valve up to 5 s
90°
Fail-safe to close (FC)
Fail-safe to open (FO)
Double acting (DA)
optical
Glass fiber reinforced polypropylene (PP-GF)
–10 to +50 °C
0 – 100 %
DN
FC/FO
10
0.15 dm
15
20
25
32
0.28 dm
40
50
3
Open
0.18 dm
3
3
Open
3
0.35 dm
DA
Closed
0.15 dm
3
Closed
3
0.28 dm