Stroke Limiter; 5.2.1 Adjusting The Stroke Limiter - GF PA11 Instructions De Service

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Instruction manual
5.2

Stroke limiter

In versions with the stroke limiter, stroke limiting is set to 90° ex works. This setting can be
changed if required. This allows the turning movement towards working position to be limited
to less than 90°, e.g. 45°.
NOTE
In versions with the DA function, limiting is possible only towards the open position.
1
Covering cap
2
Adjusting screw
3
Locknut

5.2.1 Adjusting the stroke limiter

 Check that there is no compressed air present
 Unscrew the cover (1)
 Use the control air to bring the actuator to working position
(DA function: CLOSED position)
 Loosen the locknut (3)
 Turn the adjusting screw (2) counter-clockwise (FC function) or clockwise (FO/DA function)
to obtain the desired stroke limitation
 Actuator in rest position (DA function: OPEN position)
 Test the stroke limiter. Repeat steps 3 to 6 if necessary
 Tighten the locknut (3).
 Screw on the covering cap (1)
34