5.6 Model 5300, 5350 wall-mounted controls
9
5300
I
When the fan is running: Closing the lid by pressing the UP/DOWN button shuts OFF the fan blade .
Reopening the lid using the UP/DOWN button will revert the fan blade movement to its previous set
speed . Using the ON/OFF button will not do this; the ON/OFF button resets the fan to normal operation .
Name
Fan Power ON/OFF
Fan Speed
Vent Lid OPEN/CLOSE
(Model 5350)
Vent Lid OPEN/CLOSE
(Model 5300)
Air OUT/IN
(Model 5300)
Rain Sensor LED
9
5350
•
Press to turn ON the fan (this will start the fan on HIGH) .
•
Press to turn OFF the fan (this will stop the fan and close the lid) .
•
Press UP to increase the fan speed .
•
Press DOWN to decrease the fan speed .
(The fan has 13 speeds, not including OFF .)
•
When the vent lid is closed, press this button once to open the vent lid .
•
When the vent lid is open, press this button once to close the lid .
(The rain sensor can be turned ON or OFF by pressing this button for three
seconds .)
•
When the vent lid is closed, press the UP button once to open the vent lid .
•
When the vent lid is open, press the DOWN button once to close the vent
lid .
(The rain sensor can be turned ON or OFF by pressing this button for three
seconds .)
•
When the vent lid is open, press this button once to reverse the fan blade
direction; press it again for the opposite direction . Once pressed, the
motor will slow and then reverse direction . If the button is pressed again
during the reversing cycle, a double-beep will indicate the cycle is in
progress . The function can only be changed after the reversing cycle is
complete .
•
This LED will illuminate when the rain sensor has been turned OFF at the
wall control .
•
The rain sensor can be turned ON or OFF by pressing the DOWN button
for three seconds .
Function
Fan
EN