Connecting to Electricity
▪
Connection to the 12V DC electrical supply of the recreational vehicle is made via 2 way plug (1-
480698-0) connected to the spark ignition generator.
▪
A supply cord terminating in sheathed spade connectors is recommended.
Spark generator spade connectors are for LOW voltage battery or DIRECT Current ONLY
DO NOT connect to 120 or 240 Volts AC.
Connect ONLY to protected circuit fused not more than 1 Amp
After Installation
▪
After installation the appliance MUST be tested for soundness
▪
Test ALL burners on high and low flame for flame stability.
▪
The gas supply input pressure MUST NOT rise or fall significantly from nominal when ALL appliances
connected to the supply are operated simultaneously.
▪
Test ALL gas piping and connections and make sure they DO NOT leak.
▪
Ensure that ALL packaging materials have been removed.
▪
Fix WARNING LABELS as prescribed by the current NFPA1192 & NFPA70
12V DC Spark Ignition circuit diagram
17