Hotpoint Ariston PH 640 M Instructions Pour L'installation Et L'emploi page 15

Masquer les pouces Voir aussi pour PH 640 M:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Table 1
Burner
Diameter
(mm)
Fast
100
(Large) (R)
Reduced Fast
100
(RR)
Semi Fast
75
(Medium) (S)
Auxiliary
55
(Small) (A)
Triple Crown
130
(TC)
Nominal (mbar)
Supply
Minimum (mbar)
pressures
Maximum (mbar)
*
At 15°C and 1013 mbar-dry gas
**
Propane
P.C.S. = 50.37 MJ/kg.
***
Butane
P.C.S. = 49.47 MJ/kg.
Table1 (For Hungary)
Burner
Fast (R)
Reduced Fast (RR)
Semi Fast (Medium) (S)
Auxiliary (Small) (A)
Triple Crown (TC)
Supply pressures
At 15°C and 1013 mbar-dry gas
P.C.I. G20
35,9 MJ/m
3
This appliance complies with the following European
Economic Community directives:
-
73/23/EEC of 19/02/73 (Low Voltage) and subsequent
modifications;
-
89/336/EEC
of
03/05/89
Compatibility) and subsequent modifications;
-
90/396/EEC of 29/06/90 (Gas) and subsequent
modifications;
-
93/68/EEC of 22/07/93 and subsequent modifications.
All manuals and user guides at all-guides.com
Burners and Nozzle Specifications
Thermal Power
By-pass
kW (p.c.s.*)
1/100
(mm)
Nom.
Red.
3.00
0.7
41
2.60
0.70
41
1.65
0.4
30
1.00
0.4
30
3.25
1.3
60
G 20
By-pass
Thermal
1/100 (mm)
power kW
1/100 (mm)
39
2,90
39
2,45
28
1,60
28
0,90
57
3,15
25 mbar
(Electromagnetic
Liquid Gas
Nozzle
Flow*
1/100
g/h
(1)
(mm)
***
39
86
218
39
80
189
28
64
120
28
50
73
57
91
236
28-30
20
35
Natural
P.C.S. = 37.78 MJ/m
(1) Only for appliances with the security device (Ref. F).
G 25.1
Nozzle
Thermal
Nozzle
power kW
1/100 (mm)
116
2,25
110
1,90
96
1,25
71
0,65
133
2,45
25 mbar
P.C.I. G30
122,8 MJ/m
P.C.I. G25.1
30,9 MJ/m
PH 640...
A
R
S
S
PH 640MST
A
RR
TC
S
15
Natural Gas
Nozzler
Flow*
1/100
l/h
**
(mm)
214
116
286
186
110
248
118
96
157
71
71
95
232
133
309
37
20
25
17
45
25
3
G 30
Thermal
Nozzle
power kW
1/100 (mm)
116
2,70
86
110
2,30
80
96
1,50
64
71
0,90
50
133
2,90
91
30 mbar
3
3
PH 631...
R
S
S

Publicité

Table des Matières
loading