Adjusting the Minimum Ventilation or Mist Timer
Set the selection knob to STAGE 2 - TIMER. The current Time On
is displayed, alternating with the word "On".
Use the adjustment knob to set the Time On to the desired value.
Press the push-button. The current Time Off is displayed, alternat-
ing with the word "Off".
Use the adjustment knob to set the Time Off to the desired value.
The time on and time off parameters can take values from 0 to 900 seconds,
in increments of 15 seconds. In the case of the mist timer, values range
from 1 to 60 minutes, in increments of 1 minute.
2
Adjusting the Cooling or Mist Differential
The differential for Stage 2 is the temperature difference between the moment
the fans or mist units start to run for that stage and the moment they return
to a stop (see the diagram in the Configurations Section). Differentials can be
adjusted between 0.5°F and 20.0°F (0.3°C and 11.1°C).
Set the selection knob to STAGE 2 - DIFFERENTIAL. The current
differential flashes on the display.
Use the adjustment knob to set the differential to the desired value.