Input Power Cord Installation
Choosing Conduit
Choose the appropriate conduit in
accordance with all the applicable state, local,
and national electrical codes, and standards.
Attaching Compression Lugs
Please adhere to standard processes to
properly heat shrink the tubing on the
compression lug to ensure a secure fitment
on the wire before connecting to the terminal
blocks in the station.
Installation
Refer to the following wire specification. Use
a conductor type other than RHH, RHW, and
RHW-2 with outer covering.
Choose the appropriate conductors in
accordance with all applicable, state, local,
and national electric codes and standards.
Model
Terminal
Lucid Connected
L1, L2
Home Charging
G
Station
Electrical Wiring
Electrical wiring to the charging station.
1. Fold the wire end to pass through the
conduit, and insert it into the input hole.
Choose input direction 1, 2, or 3, and
open the cap.
Note: Choose only one type, either 1, 2,
or 3.
Note: The waterproof warranty is voided
if more than one conduit is kept open.
2. Loosen the plastic screw, and open the
insulation sheet on the terminal block.
Conductor
Rating
2 AWG
90 º
Copper
8 AWG
wire
15