Art.-Nr.
Power
5424 300
50 W

Proper intended use:

The LED light is suitable for indoor lighting applications. The LED light is wired ready for
connection and comes with a connecting cable and a safety plug. The BS and swiss plug
shall be used indoors since these plug are not waterproof.
Operation:
Setting up and turning on the light
The light can be turned on and off using the switch on the back
Mounting Height: <3 m

Safety Notes:

1. Prior to commissioning, make sure the right voltage is available.
2. Prior to each use, make sure the light and mains supply cable are not damaged in any
way. Never use the lamp if you find damage.
Caution! A damaged light or mains supply cable pose a risk to life due to electric
shock!
3. Do not use the work lamp in explosive environments in which flammable liquids, gases or
dusts are present.
Risk to life!
4. LED lights are extremely bright. Do not look directly at the lamp.
5. If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively
replaced by the manufacturer or his service agent or a similar qualified person in order to
avoid a hazard.
6. Make sure the light is attached firmly and securely. Make sure the cable is not crimped or
otherwise damaged.
7. Keep children away from the lamp. Children cannot estimate the risk of electric shock.
8. Do not touch the luminares when lighted.
9. Do not make any changes to the device, the resulting damage is excluded from the
guarantee.
10. Disconnect the heater from the mains when it is not in use.
11. Warning: Never look directly into the light beam. Never direct the light beam
against people.
12. Note: The lamp is used to illuminate a workplace. It is not suitable for household room
lighting.
Non-observance of these safety instructions can result in property damage and / or
personal injury! The user is liable for any damage caused by improper use.
Nominal
Dimension
voltage
(mm)
100–240 V
240/209/252
Weight
Power
(kg)
factor
2,1
> 0,9
Current
Lumi-
Projected
nous
area (m²)
6.000 lm
0,03
0,21–
0,58 A