Berner BHFL60A Mode D'emploi page 22

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

All manuals and user guides at all-guides.com
Warning: This function only must be used by vehicle with disconnected 12V
lead-acid batteries, because the
high charging voltage 15.6V
constitutes a danger to the 12-V
on-board electronics in vehicle
systems and car paints can
damaged by battery gassing and
reduces the life of bulbs.
After selecting the reactivation
appears on the display the warning
message.
Concluded lead-gel and AGM batteries can not reactivated!
This function is intended to deeply discharged
lead-acid batteries to reactivate.
Defective lead-acid batteries (cell short) can not be reactivated.
The reactivation is started by reconnecting the battery and confirming the
"Start" button. The display shows "REACTIVATION ACTIVE".
If, instead, an error message "No battery connected" no battery or a deeply
discharged battery (Voltage of the battery is less than 3V or the battery cable
and the display switches to the main menu. By pulling the plug from the wall outlet,
the charger turns off.
With a reduced current for a limited period, the charging voltage is increased so that
the battery starts to produce gases. This results in an acid-switch into the battery
and a partial reduction of sulphate layers which has a positive effect on the
REACTIVATION
polarity is wrong) is connected. The
reactivation starts automatically as
soon as a functioning battery is
connected.
After finishing the reactivation charge
(4h) the device switches automatically
to trickle charging. This is appear in the
display.
The reactivation can be interrupted any
time by pressing the "STOP" button
21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

329144

Table des Matières