Twilight Setting
Using the Twilight Setting potentiometer you can adjust the re-
sponse threshold of the Presence Sensor between 5 and 1000
lux for twilight switch-on control. Wait until the lighting condi-
7
tions are such that the Presence Sensor should switch on.
Then turn the Twilight Setting potentiometer clockwise all the
way. Then turn it counter-clockwise until the lighting system
switches ON. You now have the twilight switch-on setting de-
sired.
Infrared (IR) Remote Control
The IR Remote has three buttons and a channel selection slide
switch as follows:
1.
2.
3.
4.
Installing the Battery into the IR Remote
Use a flat screwdriver to gently remove the cover of the
8
battery housing on the IR Remote.
Install a 12 V alkaline battery (type 23 A) and replace the
housing cover.
24
1
2
3
AUTO (automatic operation)
ON
(Lights continually ON)
OFF (Lights continually OFF)
CH
(CHannel selection)
4