Mains cable connections:
Connect the phase wire (normally brown or black) to ter-
minal "L" of the unit's terminal block.
Connect the neutral wire (normally blue) to terminal "N" of
the unit's terminal block.
Lamp connections:
Connect the phase wire of the lighting system to terminal
"LS" of the unit's terminal block.
Connect the neutral wire (normally blue) of the lighting
system to terminal "N" of the unit's terminal block.
Now attach the unit to the mounting plate.
Setting the Lighting System:
Test the presence sensor function (without the IR Remote Control)
as follows:
1. Test Mode
Go to the test position by turning both the Time Setting
and Twilight Setting potentiometers counter-clockwise all
the way to test stop (T).
Switch ON the "ON-OFF" Manual Switch. The lamps
5
should light and then extinguish after a warm-up time of
approx. 2 minutes.
Movement within the monitored area should cause the
lamps to light.
2. Settings
Time Setting
You can set the run-time, that is, how long the lamps light af-
ter the unit detects movement. The time is adjustable from
6
approx. 2 to 15 minutes. The times of 2, 5, 10 and 15 marked
on the potentiometer are approximate.
Note: The "T" position can be used to generate a short pulse
for initiating sequences or starting external timers.
23