Ribimex Ribiland MH2500-10M-V Manuel D'instructions Et D'utilisation page 6

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

CAUTION ! To reduce the risk of fire, electric shock or injury to persons during the installation and use of
your pump, it is recommended that basic safety precautions should always be taken, including the following
precaution:
Read all these instructions before starting to operate this product and keep these instructions in a safe place.
1) GENERAL
This multistage pump has been designed to suck up clear water.
It should be installed in a location that is dry, ventilated and protected from bad weather and heat. The
maximum suction height should not exceed 8 metres.
Correctly installed, your pump will function with maximum, output and should meet your requirements fully:
read the following Instructions carefully.
2) TECHNICAL CHARACTERISTICS
Ref. / Art. Nr. : PRMCA10 / 516266
Model
: MH2500-10M-V
Power supply
: 230V ~ 50Hz
Motor power
: 2700 W
Speed
: 2850 rpm
Max suction
: 8 m
H max.
: 110 m
Q max
: 90 l/min
3) INSTALLATION
a) Important recommendations;
Before connecting to the electrical supply, you must:
 Fix the pump firmly to the ground or onto a suitable support. To do this, there are two notches provided
for this purpose in the foot of the pump for securing it with bolts (not supplied).
 Check that the mains supply corresponds to that given on the pump's technical table.
WARNING
The warranty does not cover accidents due to poor installation. This pump should be installed according to
the national standards in force (NFC 15100 for France) and by qualified personnel. We advise you to call in
an electrician.
The fixed pipe works to which the pump will be connected must have a separation device with contacts of at
least 3mm opening distance at all poles.
If the pump is used for swimming pools it must be powered by a transformer with circuit breaker (RCCD)
with sensitivity not exceeding 30mA. The pump should not be used in outside fountains, garden ponds and
similar places.
N.B.: This pump is not intended for cleaning or other maintenance operations on swimming pools. When it
is used for swimming pools, it must be installed in an enclosed service area.
b) Electrical connection:
1. Remove the lid from the junction box by loosening the three crosshead screws on the top.
2. Loosen the two screws from the drawing shutdown system until the upper section slides freely and allows
a power cable to be fed through.
3. Ensure that the power cable used is not connected to the mains.
User and Maintenance Manual
(Pump MH2500-10M-V)
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Prmca10516266

Table des Matières