Hayward CrystaLogic Guide De L'utilisateur page 9

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Autonomous mode (RGB colour spotlight only).
If there is no RC unit, the spotlights operate independently and the user can choose between 18 modes: 11 fixed colours
and 7 automatic colour change sequences (see sequence table below).
Sequence
The colour change can be obtained by switching off the power to the spotlights for a very short time (<1s).
The 18 operating modes can be run through successively by switching the power on and off in this way. After mode 18, the
spotlights return to the first automatic sequence (mode 1).
To synchronise the spotlights by bringing them all back to mode 2 simultaneously, switch off the power supply for 2s.
When the spotlight is switched on after being switched off for several seconds (>4s) the spotlight lights up white for 15s,
then starts the mode it was in when it was last switched off: this allows you to obtain maximum lighting if anyone accidentally
falls into the pool.
Safety (RGB colour spotlight only).
If the temperature inside the bulb rises abnormally, a safety mechanism stops the lighting and the bulb flashes red. As soon
as the temperature returns to normal, the bulb starts operating again.
If the voltage detected is too low (>11V) or too high (>15V) the bulb stops working and flashes green. The power supply
to the spotlights must be switched off to return to normal operation.
Parts must only be replaced with genuine spare parts.
You are advised to change all the sealing parts when a bulb and/or the cable are changed.
If a fault occurs, the complete LED bulb must be replaced. Do not try to open or repair it.
If the power cord or the sheath is damaged, it must be replaced by the manufacturer, an approved service centre or a
qualified technician to avoid any risk of accident.
Page 4 of 4
Colour / Programme
1
Colour: White
2
Colour: Blue
3
Colour: Blue Lagoon
4
Colour: Cyan
5
Colour: Purple
6
Colour: Magenta
7
Colour: Pink
8
Colour: Red
9
Colour: Orange
MAINTENANCE
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
ColorLogic II / CrystaLogic
USAGE
Sequence
Colour / Programme
10
Colour: Green
11
Colour: Emerald green
12
Programme: fast colour change
13
Programme: slow colour change
14
Programme: 11 fixed colors
15
Programme: Psychedelic
16
Programme: Blue/Cyan/White
17
Programme: Random colours 1
18
Programme: Random colours 2
Rev. B