Memco Panachrome+ Guide D'installation page 8

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2D
Parallel Only
Timeout/EN81-20
Timeout Period
Cdn TMO Period
Sleep
3D
Enable
Mode
Sensitivity
Timeout Count
Second Relay
Copy Main
EN81-20 Mode
Canadian
Disabled
Audio
Beeper
Speech
Speech Volume
Speaker
OFF
Panachrome
or deactivate a further 186 diagonal beams. Choose to have
ON
parallel beams only ON or OFF
OFF
This enables/disables 2D timeout for up to 5 non-adjacent
infra-red diodes
ON
Beam timeout time (10 to 360s)
Canadian timeout time setting (not enabled)
OFF
Turn sleep mode ON or OFF. Default OFF
ON
OFF
Enable/disable 3D detection. Default OFF for 2D only
detectors (G2510 or G2540) and has no effect
ON
See Section 7 for more details
ON at Closing
3D activates when the doors are closing
ON at 800mm
3D activates when the doors are approx. 800mm apart
ON Always
3D always on with no 3D timeout
ON (10s)
3D always on with 10s 3D timeout
ON (20s)
3D always on with 20s 3D timeout
High
3D sensitivity settings. Choose according to installation. If false
Intermediate
triggering on High then choose a lower sensitivity
Low
Counts the 3D triggers (2 to 10) and disables 3D once this count
is reached. Note: resets with a 2D trigger or doors fully closed
Relay 2 mimics main relay (relay 1)
Relay 2 activates when EN81-20 conditions are not met.
This can be that a diode(s) has timed out which means the
50mm target detection is now not met, or a system fault has
developed
Canadian timeout. If a trigger is on for the timeout period (Cdn
TMO) then the relay will activate
Relay 2 disabled
OFF
Beeper off
Beep ON
Beeper active on a trigger
Beep Closing
Beeper active when the doors are closing and triggered
OFF
Speech output OFF
ON
Speech output ON
Speech volume (0 to 9). Note: 0 volume is lowest setting and
not equivalent to OFF
Internal
Enable internal speaker.
External
Enable external and disable internal speaker
has 48 parallel beams and the option to activate
+

Publicité

Table des Matières
loading

Produits Connexes pour Memco Panachrome+

Ce manuel est également adapté pour:

G851 855ml gb

Table des Matières