Troubleshooting - Grozone Control sFF4 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

D) Why SHORT or LONG delay?
Some electronic ballasts are designed to turn ON very
quickly after being turned OFF without damage. In this
case, SHORT DELAY (5 seconds) could be used. But
most electronic ballasts are not likely to work
appropriately—and can be damaged—following a
short OFF/ON cycle. See ballasts specifications or con-
tact manufacturer for more details. If you are unable to get your ballasts
specifications, it is highly recommended to use LONG DELAY (5 minutes)
setting.
E) Interrupting the 5-minute LONG DELAY:
Even if you've selected the LONG DELAY, you may need to interrupt the
5-minute delay in order to turn the lights ON immediately. To do so, just set the
sliding selector to SHORT DELAY and wait about 5 seconds for the lights to turn
ON. If desired, return the selector to original LONG DELAY setting for next cycles.
IMPORTANT NOTICE :
2.
Replace cover and tighten up screws.
Do not over tighten to prevent stripping screw threads.
Problems
Lights do not turn ON on both sides
6
OPERATION GUIDE

TROUBLESHOOTING

Actions
Check if the main circuit breaker and
the sFF4 breakers are in the ON
position and reset them if necessary.
Verify that the unit is wired properly.
Check with a licensed electrician if
there are any concerns regarding
proper installation.