Model 5666
Installation Instructions With Two Piece Arm
READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION.
NOTE: All wiring must be run in accordance with the National Electrical Code (Canadian Electrical Code in Canada) through
conduit or another acceptable means. Contact a qualified electrician if there is any question as to the suitability of
the system.
Lamp in Fixture Contains Mercury. Dispose According
to Local, State, or Federal Laws.
WARNING: Turn power off at the circuit breaker or
fuse.
1. Select a location on a flat wall with structurally sound wood and
from 10 to 25 feet (3 to 7.6 m) from the ground. The wood should
be at least one inch thick to safely secure the fixture.
2. Slide the curved section of the mounting arm into the mounting
bracket. Tighten the bolts on the mounting bracket evenly.
3. Using the mounting arm and bracket as a guide mark four mount-
ing holes. We suggest drilling 3/16" (4.8 mm) pilot holes for the
lag screws.
4. Mount the arm and bracket using four lag screws and washers
provided.
5. Place a ring of silicone caulk around mounting arm (see illustra-
tion). Slide the straight section of the mounting arm on to the
curved section aligning the predrilled holes.
6. Secure the two sections with two bolts, nuts and four washers
provided. Place silicone caulk on top of the bolts and washers
to prevent water from entering.
7. Thread your outdoor cable or flexible conduit through the mount-
ing arm.
8. Loosely connect the mounting strap to the fixture using two bolts
provided.
9. Slide the fixture on to the mounting arm until the fixture comes
to a stop. Secure the fixture to the mounting arm by tightening
the two mounting strap bolts.
10. Connect the fixture wires to the service wires using the wire nuts
provided (black to black and white to white). Push the connec-
tions as far as possible into the straight arm.
11. This fixture must be grounded. Connect the service ground under
the head of the green ground screw and secure to the mounting
strap.
12. Install the lens/reflector assembly with two screws and washers
provided.
13. Screw in the 100 watt H.P. Sodium type S54 lamp provided.
14. Loosen the screw in the center of the photocontrol socket two
turns.
• If pole mounted, turn the socket so that the arrow points
North.
© 2012 HeathCo LLC
Dusk-to-Dawn Security Light
• If wall mounted, turn the socket so that the arrow points directly
away from the wall.
Note: There is a stop to prevent the socket from turning all the
way around. If you have trouble turning the socket, try turning
it the other direction. Retighten the screw in the center of the
socket.
15. Align the photocontrol (it will only plug-in one way). Plug it in
and twist clockwise until it stops.
To test operation during daylight, cover the photocontrol with a
small box. Turn on the power. Not all photocontrols are alike. Some
may have a time delay of a few minutes, others will turn on as soon
as power is applied. The light will take up to ten minutes to reach
full brightness. Uncover the photocontrol and your unit will operate
automatically—on at dusk, off at dawn.
Mounting Strap
Lens/Reflector
Assembly
100 Watt H.P.S.
Photocontrol
Mounting
Arm
Silicone
Caulk
Ground
Screw
Lag Screw (4)
Mounting
Flat Washer (10)
204060-01A
Bracket