Promass 64
Sensor A
➂
Sensor F
➂
Sensor M
➂
➀
Transmitter Promass 64 in:
EEx de [ib] IIB/IIC or EEx d [ib] IIB/IIC resp.
EEx de [ib/ia] IIB/IIC or EEx d [ib/ia] IIB/IIC
➁
PRO-LINE Ex d housing in:
EEx d resp. EEx de
(an appropriate cable entry is to be selected,
depending on the type of protection)
➂
Sensor in EEx ib IIC:
PROMASS A
DN 2...4
PROMASS F
DN 8...50
PROMASS M
DN 8...50
➃
The maximum permitted cable length is 120 m
when using cable type (6 Li9YCY 0.38 mm
however for signal reasons, the maximum cable length
is limited to 20 m.
➄
For ambient and fluid temperature ranges,
and temperature class, see page 4
Endress+Hauser
Hazardous area
II2G (ATEX)
➀
➃
➄
➀
➃
➄
➀
➃
➄
Zone 1 (CENELEC)
Hazardous area
2
) FCY,
II3G (ATEX)
➁
PROMASS 64
➁
PROMASS 64
➁
PROMASS 64
Zone 2 (CENELEC)
➀
Transmitter Promass 64 in:
EEx de [ib] IIB/IIC or EEx d [ib] IIB/IIC resp.
EEx de [ib/ia] IIB/IIC or EEx d [ib/ia] IIB/IIC
➁
PRO-LINE Ex d housing in:
EEx d resp. EEx de
(an appropriate cable entry is to be selected,
depending on the type of protection)
➂
Sensor in EEx ib IIB:
or
PROMASS F
DN 80...100
PROMASS M
DN 80
➃
The maximum permitted cable length is 120 m
when using cable type (6 Li9YCY 0.38 mm
however for signal reasons, the maximum cable length
is limited to 20 m.
➄
For ambient and fluid temperature ranges,
and temperature class, see page 4
en
Safe area
Safe area
2
) FCY,
3