Air Supply; Lubrication - Power Fist 8064685 Manuel Du Propriétaire

Ponceuse pneumatique de 6 po (à double mouvement)
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Description
This sander has a dual pad motion creating a patternless, swivel-free finish. It has built-in requlators for positivie speed
control, and front exhaust. The black button on the handle can adjust the flow of air; ideal for sanding jobs like feather
edging, metal preparation and blending body.

Air supply

1. Ensure air valve (or trigger) is in the "OFF" position before connecting to the air supply.
2. You will require an air pressure of 90 PSI, and an air flow according to specifications.
3. WArninG! ensure the air supply is clean and does not exceed 90 psi while operating the tool. too
high an air pressure and unclean air will shorten the product life due to excessive wear, and may be
dangerous causing damage or personal injury.
4. Drain the air tank daily. Water in the air line will damage the tool.
5. Clean air inlet filter weekly.
6. Line pressure should be increased to compensate for unusually long air hoses (over 8 metres). The hose
diameter should be 3/8" I.D.
7. Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain that all connections
are secure.

lubricAtion

An automatic in-line filter-regulator-lubricator is recommended (Fig 1) as it increases tool life and keeps the tool in
sustained operation. The in-line lubricator should be regularly checked and filled with air tool oil. Proper adjustment
of the in-line lubricator is performed by placing a sheet of paper next to the exhaust ports and holding the throttle
open approximately 30 seconds. The lubricator is properly set when a light stain of oil collects on the paper. Excessive
amounts of oil should be avoided.
In the event that it becomes necessary to store the tool for an extended period of time (overnight, weekend), it should
receive a generous amount of lubrication at that time. The tool should be run for approximately
30 seconds to ensure oil has been evenly distributed throughout the tool. The tool should be stored in a clean and dry
environment.
• It is very important that the tool be properly lubricated by keeping the air line lubricator filled and correctly
adjusted. Without proper lubrication the tool will not work properly and parts will wear prematurely.
• Use the proper lubricant in the air line lubricator. The lubricator should be of low air flow or changing air flow
type, and should be kept filled to the correct level. Use only recommended lubricants, specially made for
pneumatic applications. Substitutes may harm the rubber compounds in the tools O-rings and other rubber
parts.
iMportAnt!
if a filter/regulator/lubricator is not installed on the air system, air operated tools
should be lubricated at least once a day or after 2 hours work with 2 to 6 drops
of oil, depending on the work environment, directly through the male fitting in the
tool housing.
loADinG AnD operAtion
fig. 1
tool
For any technical questions, please call 1-800-665-8685