Overview
Refer to the illustrations on page 2 of this manual.
1
DST mode
2
time
3
radio-controlled clock
4
weekday
5
date
6
moon phase
7
weather forecast
8
absolute/relative barometric pressure
9
barometric pressure
10
outdoor sensor
11
outdoor temperature
12
max. outdoor temperature
5.
Operation
5.1
Powering and Installation
The weather station will enter data reception mode as soon as the batteries have been
inserted. Therefore, we recommend placing the batteries in the thermo-hygrometer
first. Then, power the receiver console within 5 seconds time to optimize data
transmission and reception.
Do not puncture batteries or throw them in fire as they may explode. Do not attempt
to recharge non-rechargeable batteries (alkaline). Dispose of batteries in accordance
with local regulations. Keep batteries away from children.
Power both the thermo-hygrometer and receiver console.
Install the remote thermo-hygrometer at a distance of 5 to 10 meters away from the receiver console.
We recommend installing the thermo-hygrometer in a vertical position on a shaded north-facing wall, at
the same height as or above the receiver console.
Wireless communication is susceptible to interference, distance, walls and metal barriers.
Electro-Magnetic Interference (EMI)
Keep the thermo-hygrometer away from monitors, computers, etc.
Radio Frequency Interference (RFI)
Keep the thermo-hygrometer away from other devices using the 433 MHz frequency.
Line of Sight
The thermo-hygrometer has a range of 100 m (no interference, barriers or walls). Considering all
obstacles, the range will be about 30 m.
Metal Barriers
Radio waves will not pass through metal such as aluminium. Consider all metal barriers when
installing the sensors.
5.2

DCF-Signal Reception

Once both the thermo-hygrometer and receiver console powered, allow the signal to stabilize for about
30 minutes. If the signal reception is not successful, the system will automatically resume every two
hours until the signal is captured.
V. 01 – 05/07/2017
WS2800MP
13
min. outdoor temperature
14
outdoor humidity
15
min. outdoor humidity
16
max. outdoor humidity
17
indoor temperature
18
max. indoor temperature
19
min. indoor temperature
20
indoor humidity
21
min. indoor humidity
22
max. indoor humidity
23
max./min. daily icon
REMARK
WARNING
4
©Velleman nv