Initial Startup; Operation; Ending Operation; Transport - Kärcher IVR 100/24-2 Ef Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
Equipotential bonding cable
9
Collection container
10
Push handle
11
Steering rollers with parking brake
12
Angular outlet
13

Initial startup

See graphics pages for illustration
1. Bring the device into the working posi-
tion.
2. If necessary, secure the device using the
parking brake.
3. Ensure that the suction head is fitted
correctly.
4. Insert the suction hose into the suction
hose connection.
Illustration B
5. Plug the desired accessory onto the suc-
tion hose.

Operation

See graphics pages for illustration
1. Plug the mains plug into the socket.
2. Switch on the device using the trigger.
Illustration C
The switch has multiple level settings:
0 The device is off.
1 Motor 1 is switched on.
2 Motors 1 and 2 are switched on.
3. Start the vacuuming process.
Cleaning the dust filter
See graphics page for illustration
Note
Clean the filter regularly to avoid declining
suction power.
Illustration D
1. Move the filter cleaning handle back and
forth several times to clean the filter.
Empty the collection container via
the inclined outlet
See graphics page for illustration
Emptying using manual emptying flap
Illustration E
1. Switch off the device.
2. Clean the dust filter.
3. Move the device to a suitable emptying
station.
4. Engage the roller brakes.
5. Empty the collection container:
 Above an emptying station
a Pull the hand lever up.
The manual emptying flap opens.
 Using a forklift, above a container
a Lift the device above the chassis using
the forklift.
b Lift the device.
c Open the manual emptying flap above
the container.
 Using a crane, above a container
a Hook the snap hooks of the crane
bracket (accessory) into the crane
grommets on the device.
b Lift the device
c Open the manual emptying flap above
the container.
 Into an underfloor conveyor
a Open the manual emptying flap above
the feed opening.
6. Push the hand lever down.
The collection container is closed.
Removing the suction head
See graphics page for illustration
1. Switch off the device and disconnect
from the power supply.
2. Open the suction head lock.
Illustration F
3. Remove the suction head and put it to
one side.

Ending operation

1. Switch off the device using the on/off
switch
2. Empty and clean the collection contain-
er.
3. Remove the accessories and clean and
dry them as necessary.
CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during
transport and storage.
1. When transporting in vehicles, secure
the device against slipping and tipping
over according to the applicable guide-
lines.
English