Table des Matières

Publicité

Manual BVS 21 ATEX E 070
3.
Technical data
3.1
Marking
3.1.1 Areas with gas explosion hazard
II 2G
Ex eb IIC Gb
3.1.2 Areas with dust explosion hazard
II 2D
Ex tb IIIC Db
3.2

Certification

3.2.1 EU type-examination certificate
BVS 21 ATEX E 070
3.2.2 IECEx Certificate Conformity
IECEx BVS 21.0073
3.3
Enclosure ingress protection
Minimum degree of protection
Enclosure material
Perm. ambient
temperature
4.
Installation
The generally recognized rules of engineering,
IEC 60079-14 "Design, selection and erection of
electrical installations", national regulations and
these operating instructions apply for the instal-
lation and operation.
4.1
Mounting
The safety valve is mounted on the top of the
enclosure or equipment to be protected by
means of the M 25 x 1.5 mm thread and is then
tightened and locked with the counter nut sup-
plied with it.
4.2
Rated reaction pressure
The valve insert is set in the factory at a pressure
of 15-20 mbar (150-200 Pa) and, for safety rea-
sons, it must not be altered.
Edition August 2022
Copyright
IP 66
Anodized aluminium or
stainless steel
–50°C to 80°C
thuba Ltd., CH-4002 Basel
Switzerland
5

Publicité

Table des Matières
loading

Table des Matières