Brizo T75 Serie Instructions D'installation page 7

Masquer les pouces Voir aussi pour T75 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Trim Installation
3
B.
1
Volume Handle Installation
Install volume control handle (1) over valve
cartridge (2).
Using a allen wrench, insert set screw (3) into
handle (1). Applying pressure, insert set screw
cover (4) until properly seated.
Installation and Adjustment of the Temperature Knob
Failure to do so may cause injury.
C.
1
3
Adjust temperature limit stop! Turn on water
supplies; LET THE WATER RUN AT BOTH
FULL HOT AND FULL COLD TO ENSURE
THE WATER IS RUNNING AS HOT/COLD AS
POSSIBLE. Place a thermometer in a plastic
tumbler, and hold the tumbler in the water stream.
Place the temperature knob (1) onto the splines
(2), insert temperature handle (3), then rotate
the temperature handle counter-clockwise until
you achieve your maximum desired temperature
from the outlet (not more than 120° or the lower
temperature mandated by your local plumbing
code).
2
3
4
2
75 Series Installation
5
If max temperature is not achieved before limit
stop (5) on temperature knob (1) meets the
limit stop (4) on the volume control handle.
Remove the temperature control knob (1) from
splines (2). Rotate temperature control knob
(1) clockwise. Place temperature control knob
(1) back onto splines (2) and continue to rotate
counter-clockwise until maximum desired
temperature is achieved.Remove the temperature
knob (1) and replace onto thesplines (2), making
sure that the temperature knob limit stop (5)
hits against the volume handle limit stop (4) as
shown.
5
4
82666 Rev. G

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

T75561T75661

Table des Matières