PROBLEM SOLUTION

1. WHY DOES THE DRILL NOT TURN ON WHEN YOU
PRESS THE SWITCH?
The forward/reverse rotation control, which is on top of
the trigger, is positioned in the lock function. Unlock the
forward/reverse rotation control by putting it into the
required rotation position. Push the trigger and the drill
will start to rotate.Check that the battery is charged and
properly connected to the tool.
2. THE DRILL STOPS BEFORE THE SCREW IS
COMPLETELY TIGHTENED. WHY?
Verify the torque position of the torque adjusting ring.
Find the torque adjusting ring between the chuck and the
drill body. Position 1 is the lowest torque (screw driving
force) and position 15 is the highest torque (screw driving
force). Position is for drill operation. Regulate the torque
adjusting ring to a higher position to reach the best result.
3. REASONS FOR DIFFERENT BATTERY PACK
WORKING TIMES
Charging time problems, as above, and having not used a
battery pack for a prolonged time will reduce the battery
pack working time. This can be corrected after several
charge and discharge operations by charging & working
with your drill. Heavy working conditions such as large
screws into hard wood will use up the battery pack energy
faster than lighter working conditions. Do not re-charge
your battery pack below 0
o
affect performance.
MAINTENANCE
Remove the battery pack from the tool before
carrying out any adjustment, servicing or
maintenance.
Your tool requires no additional lubrication or
maintenance.
There are no user serviceable parts in your power
tool. Never use water or chemical cleaners to clean
your power tool. Wipe clean with a dry cloth. Always
store your power tool in a dry place. Keep the motor
ventilation slots clean. Keep all working controls free
of dust. Occasionally you may see sparks through the
ventilation slots. This is normal and will not damage your
power tool.
FOR BATTERY TOOLS
The ambient temperature range for the use and
storage of tool and battery is 0
The recommended ambient temperature range for the
charging system during charging is 0
20V Cordless Drill Driver
C and above 45
o
C as this will
0
0
C-45
C.
0
C-40
0
C.
ENVIRONMENTAL PROTECTION
Waste electrical products must not be disposed
of with household waste. Please recycle where
facilities exist. Check with your local authorities
or retailer for recycling advice.
DECLARATION OF CONFORMITY
We,
Positec Germany GmbH
Postfach 32 02 16, 50796 Cologne, Germany
Declare that the product
Description Cordless Drill Driver
Type WX101 WX101.X (1-designation of machinery,
representative of Cordless Drill)
Function Drilling, tightening and loosening
screws, nuts
Complies with the following Directives:
2006/42/EC
2011/65/EU&(EU)2015/863
2014/30/EU
Standards conform to
EN 55014-1, EN 55014-2, EN 62841-1, EN 62841-2-1
The person authorized to compile the technical file,
Name
Marcel Filz
Address Positec Germany GmbH
Postfach 32 02 16, 50796 Cologne, Germany
2021/03/20
Allen Ding
Deputy Chief Engineer, Testing & Certification
Positec Technology (China) Co., Ltd
18, Dongwang Road, Suzhou Industrial
Park, Jiangsu 215123, P. R. China