Function; Hold Mode - Baxtran OPTIMA Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16

3.4 FUNCTION

3.4.1 AFTER STARTING AND SELF-CHECK, LONG PRESS
OFF mode
DNY mode

HOLD mode

ALAR mode
3.4.2 DNY MODE
Long press
to enter setting, and press
sensitivity. Choose 1/2/3, press
on the right side of the panel.
In this mode, the sudden peaks and lows of a moving object are filtered to display a more stable value. It is commonly used in animal husban-
dry departments, such as weighing animals.
Other key functions are not affected.
When the dynamic measurement is stable, the buzzer gives a short sound, indicating the measurement is stable.
Dynamic weighing mode:
1 weak dynamic
2 strong dynamic
3 Locking dynamics (no update after locking unless back to zero)
To come back to normal mode, press and hold
3.4.3 HOLD MODE
Long press
to enter setting, and press
The mode is confirmed by function indicator light on the right side of the panel.
Other key functions are not affected.
In the open state, record the peak of the measured weight and keep it. The retained value is displayed when the subsequent measured value is
not greater than the retained value. When subsequent measurements exceed the current peak value, the new peak value is displayed and held.
To come back to normal mode, press and hold
3.4.4 CHECKWEIGHER MODE
Long press
to enter setting, press
press
to input upper limit value.
Press
to confirm the upper limit value and move to the next setting, this is to choose the type of alarm mode.
Choose 0/1/2, and press
right side of the panel.
When entering the upper and lower limit values, the
the digits to the left.
Alarm mode selection:
0 Turn off alarm
1 Alarm sounds when the weight is within upper and lower limits
2 Alarm sounds when the weight is outside upper and lower limits.
To come back to normal mode, press and hold
Turn OFF all other function modes
Dynamic measurement mode
Peak retention mode
Upper and lower limit mode
repeatedly until 2 DnY is displayed, Press
to confirm and enter the Dynamic weighing mode. The mode is confirmed by function indicator light
, 1Off will be displayed. Press
repeatedly until 3 hold is displayed, Press
, 1Off will be displayed. Press
repeatedly until 4 alar is displayed. Press
to confirm. Now you have entered the Alarm mode. The mode is confirmed by function indicator light on the
increases the digit value, the
, 1Off will be displayed. Press
TO ENTER THE FUNCTION SELECTION:
and the scale will return to normal mode.
and the scale will return to normal mode.
to input the lower limit value. When done,
selects the digits to the right, and
and the scale will return to normal mode.
OPTIMA USERS GUIDE
to move to the next step of selecting
to confirm entering peak retention mode.
EN
EN
selects
13