Télécharger Imprimer la page

HOMCOM 820-300V90 Manuel D'instructions page 9

Cheminée électrique

Publicité

Les langues disponibles

Les langues disponibles

Assembly Instructions
Ensure the heater is switched off and unplugged, then turn the heater upside
down.
① Fix the two plates on both
right and left sides with
eight screws.
Overheating safety device
If the heater stops working, turn it off and check if the inlet or outlet is blocked. Unplug
the unit and wait at least 10 minutes, so the protection system can reset. If the heater
still does not work, contact customer service for inspection or repair.
Before restarting the heater, ensure it has been unplugged for at least 10 minutes.
Table for information requirements for electric local space heaters.
Model identifier(s):YH-20-1B
Item
Symbol
Heat output
Nominal heat
Pnom
output
Minimum
Pmin
heat output
(indicative)
Maximum
Pmax
continuous
heat output
Auxiliary electricity consumption
At nominal
elmax
heat output
② Fix the back plate with
four screws.
Value
Unit
Type of heat input, for electric storage local
space heaters only (select one)
Manual heat charge control with
1,8 – 2,0
kW
integrated thermostat
Manual heat charge control with
kW
1,0
room and/or outdoor temperature
feedback
Electronic heat charge control with
room and/or outdoor temperature
kW
2.0
feedback
Fan assisted heat output
Type of heat output/room temperature
kW
N/A
control (select one)
9
③ Fix the bottom plate with four
screws.
Item
Unit
[no]
[no]
[no]
[no]

Publicité