Micrometric regulation
Turn the horizontal regulation knobs to change the coarseness of the
ground coffee. Micrometric regulation does not require blocking. Regulate
the grinder with the motor turned on if there is any coffee in the grinder,
with it turned off if it is empty (see figure F3). "+" shows the rotation
direction to increase the coarseness of the ground coffee. "- " to decrease
the coarseness of the ground coffee. We recommend grinding and using a
few grams of coffee each time you change the coarseness, which will help
remove the small amount of ground coffee already inside the grinder.
If the coffee flow is too slow it means that the ground coffee is too fine,
while if the flow is too fast it means the ground coffee is too course.
Many other factors can also affect the coffee flow, such as the amount of coffee, how much it has been pressed, the
appliance adjustment, the cleanliness of the filters and the climatic conditions.
12
PROGRAMMING
Switch on the appliance to enter the programming menu. After the welcome message, press the select button (10 seconds
or until the wording on the display changes).
Scroll through the menu by turning the select button. When the function to be changed is displayed, press it to enter and
change the parameters.
To exit the programming menu, turn the select button, and when the wording "EXIT" appears on the display, press it to
confirm and return to the operating menu.
12-1
PROGRAMMED DOSES
To enter the programming menu, turn on the appliance. After the welcome message appears, press the select button (10
seconds or until the wording on the display changes).
The appliance has digital dose adjustment.
Scroll through the programming menu by turning the select button. When the dose to be adjusted is displayed, press it to
start programming.
Turn the select button to adjust the time shown on the display. The time will increase when it is turned clockwise and
decrease when it is turned anti-clockwise.
When the required time has been set, press the select button to confirm the value and return to the programming menu.
Proceed with adjusting the next dose.
The software is equipped with three programmable doses. Dose No.3 can be disabled (OFF) by turning the select button
anti-clockwise.
12-2
CONTINUOUS DOSE
To enable or disable the continuous dose, proceed as follows: scroll through the programming menu by turning the select
button. When the Dose symbol is displayed, continue pressing it to enter.
Turn the select button to enable or disable the function. Then press it to confirm and return to the programming menu.
From the operating menu you can now choose the continuous dose, if enabled.
The appliance can only operate in the continuous dose mode for short periods. Never exceed the time of one minute
continuously in order to prevent the motor from overheating.
12-3
D.T.S. (DOSING TYPE SELECTION)
The D.T.S. function allows you to decide how to select the dose.
20
ENGLISH
+
-
F3